🔧 RO Storage Tank Not Filling / Fills Very Slowly? Complete Fix Guide

⚠️

Problem Overview

Is your RO water purifier's storage tank not filling at all, or taking 4-8 hours instead of the normal 1-2 hours to fill completely? This frustrating problem affects thousands of Indian households daily, leaving families without adequate drinking water. The issue can stem from multiple causes: auto shut-off valve malfunction (40% of cases), low inlet water pressure (25%), clogged pre-filters or membrane (20%), bladder air pressure loss (10%), or flow restrictor problems (5%). This comprehensive guide helps you diagnose the exact cause and provides both DIY fixes and professional solutions with Indian market pricing.

Safety First

  • !
    Turn off water supply: Always turn off the inlet water supply valve before opening any filter housings or working on internal components to prevent flooding.
  • !
    Depressurize the tank: Open the RO tap and drain at least 2-3 liters to release pressure before working on the storage tank or auto shut-off valve.
  • !
    Never over-inflate tank: When adding air to storage tank bladder, never exceed 10 PSI. Over-inflation can rupture the bladder and damage the tank permanently.
  • !
    Use food-grade parts only: Always use genuine or certified food-grade replacement parts. Cheap aftermarket valves and filters can contaminate drinking water.
  • !
    Hygiene is critical: Wash hands thoroughly before handling any internal components. Sanitize all tools and parts with clean water before reassembly.

🔍 Quick Diagnostic Checks ⏱️ 10-15 minutes

1 Check Tank Filling Rate

Empty tank completely. Turn on inlet supply and time how long it takes to fill 50%. Normal: 30-45 minutes. Slow: 1-2 hours. Critical: >2 hours for half-fill.

2 Test Auto Shut-Off Valve

Listen carefully near the RO unit when tank is nearly full. You should hear a distinct click when valve shuts off. No click = valve malfunction (40% of tank filling issues).

3 Verify Inlet Water Pressure

Check inlet tap pressure. Open it fully - water should flow strongly. Weak flow = low pressure issue. Ground floor apartments often have <40 PSI, causing slow tank filling.

4 Check Pre-Filter Condition

Look at sediment filter (first stage). If brown/yellow with visible sediment or water-filled between filter and housing, it's severely clogged and blocking tank fill.

5 Test Reject Water Flow

Place reject/drain tube in bucket. Water should flow continuously and steadily when tank is not full. Very weak or no reject water = membrane or system blockage.

6 Inspect Tank Air Pressure

Empty tank fully. Check air valve at back/bottom (like bicycle valve). Press gently - should release air. No air = bladder deflated, tank won't fill properly.

📊 Understanding Normal RO Tank Filling Times

💡 Normal Tank Filling Time: 1-2 hours for 8-10 liter storage tank

RO purification is inherently slow (10-15 LPH). Tank fills gradually while purifying. However, >3 hours indicates a problem that needs fixing.

Tank Capacity Normal Fill Time Slow Fill Time Critical Fill Time Status
7-8 Liters 45-75 minutes 90-150 minutes >150 minutes ✅ Standard
10-12 Liters 60-90 minutes 120-180 minutes >180 minutes ✅ Large Tank
8-10 Liters 60 minutes 120-240 minutes >4 hours ⚠️ Needs Service
Any Size - - >6 hours or Never Fills 🚨 Urgent Repair

Factors Affecting Tank Filling Speed:

  • Inlet water pressure: Higher pressure = faster filling (minimum 40 PSI required for standard RO)
  • Input water TDS: Higher TDS = slower purification and tank filling (membrane works harder)
  • Auto shut-off valve: Malfunctioning valve may close prematurely, stopping tank fill early
  • Filter condition: Clogged pre-filters drastically reduce flow rate to tank
  • Water temperature: Cold winter water (10-15°C) flows slower than warm water through RO membrane
  • Membrane age: Older membranes (>2-3 years) produce slower flow and take longer to fill tank

💡 Common Causes → Solutions

Problem

Auto Shut-Off Valve Malfunction (40% of cases)
Pressure-sensing valve fails to open when tank pressure drops, or closes prematurely when tank is only partially full. Tank never reaches full capacity or takes extremely long time.

Solution

Adjust or Replace Auto Shut-Off Valve
Professional adjustment or replacement. Cost: ₹300-₹800 for valve + labor. Fixed in 30-45 minutes. Resolves 40% of tank filling problems.

Problem

Low Inlet Water Pressure (<40 PSI) - 25% of cases
Municipal supply pressure too low, especially on ground floors and during peak hours (morning 6-9 AM, evening 7-10 PM). RO cannot push water through membrane efficiently.

Solution

Install Booster Pump
Professional installation required. Cost: ₹2,000-₹5,000 (pump) + ₹500-₹1,000 (labor). Increases pressure to 60-80 PSI, doubles filling speed.

Problem

Clogged Sediment/Carbon Pre-Filters - 15% of cases
Filters saturated with sediment and dirt, severely restricting water flow to RO membrane. Tank fills extremely slowly due to reduced flow rate.

Solution

Replace Pre-Filters
Easy DIY fix. Cost: ₹400-₹600 (sediment + carbon filters). Takes 15-20 minutes. Tank filling speed improves dramatically in most cases.

Problem

Storage Tank Bladder Air Pressure Loss - 10% of cases
Bladder inside tank deflated (should be 6-8 PSI air pressure when empty). Tank can't push water out efficiently, and filling appears slow or incomplete.

Solution

Repressurize Tank Bladder
Easy DIY fix. Empty tank, add air to 6-8 PSI using bicycle pump. Free if you have pump. Takes 10 minutes. If pressure drops frequently, replace tank (₹1,200-₹2,500).

Problem

Fouled RO Membrane - 5% of cases
Membrane surface scaled with hard water deposits (TDS >500 ppm areas). Produces water very slowly, taking hours to fill even small amounts in tank.

Solution

Replace RO Membrane
Professional replacement required. Cost: ₹1,500-₹4,000 (membrane) + ₹300-₹800 (labor). Replace every 2-3 years (1.5 years in hard water areas).

Problem

Flow Restrictor Clogged - 3% of cases
Capillary tube regulating reject water flow blocked with mineral deposits. Reduces system pressure and flow rate, slowing tank filling significantly.

Solution

Clean or Replace Flow Restrictor
Professional service required. Cost: ₹150-₹400 for cleaning/replacement. Usually done during annual RO service. Takes 20-30 minutes.

Problem

Tubing Kinks or Blockages - 2% of cases
Tubes connecting tank to RO unit kinked, pinched, or blocked. Water cannot flow freely to storage tank even though purification is happening.

Solution

Inspect and Straighten Tubes
Easy DIY visual inspection. Trace all tubes from unit to tank. Straighten any kinked sections. Ensure smooth, gradual bends. Free fix, takes 10-15 minutes.

🛠️ DIY Fixes You Can Try Now

1

Measure Actual Tank Filling Time

How to do it: Empty the storage tank completely (open tap until water stops). Close tap and note the start time. Let tank fill undisturbed for 1 hour. Check how much water accumulated (open tap and collect in measuring jug).

What to expect: Normal = 5-7.5 liters in 1 hour (60-75% of 10L tank). Slow = 3-5 liters in 1 hour. Critical = <3 liters in 1 hour. This helps identify severity of problem.

💡 Pro Tip: Test at different times (morning vs evening). If filling speed varies dramatically, the issue is inlet water pressure fluctuation, not RO system malfunction. Consider booster pump installation.
2

Check and Adjust Storage Tank Air Pressure

What you need: Bicycle pump with pressure gauge (or standalone tire pressure gauge), screwdriver (if air valve is covered), bucket.

Step-by-step process:

  1. 1. Turn off inlet water supply valve to RO system completely
  2. 2. Open RO tap and drain storage tank 100% (keep tap open until no water comes out)
  3. 3. Locate air valve on storage tank - usually at back or bottom (looks like bicycle tire valve)
  4. 4. Remove dust cap from air valve
  5. 5. Press pressure gauge firmly on valve to measure current pressure
  6. 6. If pressure is below 6 PSI or zero, bladder is deflated
  7. 7. Add air using bicycle pump to exactly 6-8 PSI (DO NOT exceed 10 PSI - can rupture bladder)
  8. 8. Remove pump, replace dust cap on air valve
  9. 9. Turn on inlet water supply
  10. 10. Let tank fill completely (1-2 hours) and test - dispensing should be faster
💡 Pro Tip: Check tank pressure every 6 months as preventive maintenance. If bladder loses pressure within 2-3 months repeatedly, the bladder has a leak and entire tank needs replacement (₹1,200-₹2,500).
3

Replace Sediment and Carbon Pre-Filters

What you need: New sediment filter (₹200-₹300), new carbon filter (₹200-₹300), filter wrench (usually provided with RO), bucket to catch water, clean cloth.

Detailed steps:

  1. 1. Turn off inlet water supply valve completely
  2. 2. Release system pressure by opening RO tap and draining 2-3 liters
  3. 3. Place bucket under first filter housing (sediment filter)
  4. 4. Use filter wrench to turn housing counterclockwise (may need firm grip)
  5. 5. Remove old sediment filter - note color and sediment accumulation
  6. 6. Clean inside of housing with clean water, check O-ring for cracks
  7. 7. Apply thin layer of food-grade silicone grease to O-ring
  8. 8. Insert new sediment filter (ensure it sits properly at bottom)
  9. 9. Screw housing back tightly hand-tight (don't over-tighten - can crack housing)
  10. 10. Repeat steps 3-9 for carbon filter (second housing)
  11. 11. Turn on water supply slowly, check all housings for leaks
  12. 12. Flush system by letting 2-3 tanks of water run to waste before drinking
  13. 13. Test tank filling speed - should improve noticeably within 30 minutes
💡 Pro Tip: Always replace both sediment and carbon filters together for maximum benefit. Mark installation date on housing with permanent marker. In hard water areas (Delhi, Chennai, Mumbai bore water), replace every 4-6 months instead of standard 6-12 months.
4

Inspect Tubing for Kinks and Blockages

What to check: Trace all colored tubes (white, blue, yellow, red) from RO unit to storage tank to faucet. Look for sharp bends (>90 degrees), pinched sections, or tubes pressed against walls/cabinets.

Common problem locations:

  • • Blue tube (purified water line) from RO to tank - most critical for tank filling
  • • Behind RO unit where tubes connect to wall inlet
  • • Under sink where tubes route through cabinet walls
  • • At tank connection points - tubes often bent sharply here
  • • Where tubes pass through drilled holes in cabinet

How to fix: Gently straighten any sharply bent tubes. Ensure all bends are gradual and smooth. Re-route tubes if necessary to avoid tight spaces. If tube appears permanently creased, consider replacing that section (₹50-₹100 per meter).

💡 Pro Tip: Take photos before straightening or re-routing so you can restore original configuration if needed. Most important tube for tank filling is the blue line (purified water) - focus on this first.
5

Test Auto Shut-Off Valve Operation (Advanced DIY)

How to test: This valve automatically stops water production when tank is full (based on pressure). Empty tank completely. Start filling tank and listen carefully near RO unit. When tank reaches 70-80% full, you should hear a distinct "click" sound as valve closes.

Diagnosis:

  • • Valve clicks when tank is only 30-40% full = valve closing too early (malfunction)
  • • No click sound even when tank is 100% full = valve stuck open (rare, causes water waste)
  • • Clicks but tank still fills very slowly = valve working, problem is elsewhere (filters/pressure/membrane)
  • • Valve clicks but reject water continues flowing = valve partially stuck, needs cleaning or replacement

Simple adjustment: Some valves have a small screw adjustment. Turning clockwise makes it close earlier (lower tank capacity), counterclockwise makes it close later (higher capacity). Adjust 1/4 turn at a time and test.

💡 Pro Tip: If adjustment doesn't help or you're not confident, call professional for valve replacement (₹300-₹800 total cost). Wrong adjustment can damage valve permanently or cause tank overfilling/leakage.

📞 When to Call a Professional

🔧 Professional Service Required

  • • Auto Shut-Off Valve Replacement
    Cost: ₹300-₹800 (valve + labor)
    Time: 30-45 minutes
    When: Tank never fills completely or stops at 30-50%
  • • RO Membrane Replacement
    Cost: ₹1,500-₹4,000 (membrane) + ₹300-₹800 (labor)
    Time: 45-60 minutes
    When: Tank fills <5 liters per hour even after filter replacement
  • • Booster Pump Installation
    Cost: ₹2,000-₹5,000 (pump) + ₹500-₹1,000 (installation)
    Time: 1-2 hours
    When: Inlet pressure consistently <40 PSI (ground floor)

💰 Component Replacement Costs

  • • Storage Tank (if bladder damaged)
    Cost: ₹1,200-₹2,500
    When: Bladder loses pressure within weeks repeatedly
  • • Flow Restrictor Cleaning/Replacement
    Cost: ₹150-₹400
    Time: 20-30 minutes
  • • Complete RO Service (Annual)
    Cost: ₹500-₹1,200
    Includes: Filter check, TDS check, valve inspection, sanitization
  • • Complete Filter Set Replacement
    Cost: ₹800-₹1,500
    Includes: All pre-filters, post-carbon filter

🚨 Red Flags - Call Professional Immediately

  • • Tank has not filled at all in 6+ hours with inlet water supply on
  • • Water leaking from auto shut-off valve or storage tank connections
  • • Strange buzzing or grinding noise from RO unit when tank is empty
  • • Reject water flowing continuously even when tank is full (water waste)
  • • Output water TDS suddenly increased (>50 ppm when input is 200-300 ppm)
  • • Tank bladder deflates within 1-2 weeks of adding air (bladder punctured)
  • • Multiple DIY fixes attempted but tank still fills <5 liters in 2 hours

🏢 Brand-Specific Considerations for India

💡 Most common brands in India: Kent, Aquaguard, Pureit, Livpure, HUL Pureit, AO Smith

Each brand has slightly different auto shut-off valve designs and tank configurations. Always refer to your specific model manual for valve adjustment procedures.

Brand Typical Tank Size Normal Fill Time Common Issue Service Contact
Kent RO Systems 8-9 Liters 60-90 min Auto shut-off valve sensitive, often closes early 1800-123-1000
Aquaguard (Eureka Forbes) 7-8 Liters 50-75 min Pre-filter clogging common in hard water 1860-210-1000
Livpure RO 8-10 Liters 60-100 min Tank bladder pressure loss common after 2-3 years 1800-111-0808
HUL Pureit 6-7 Liters 45-70 min Low pressure areas need booster (not always included) 1800-102-7424
AO Smith Z-Series 10-15 Liters 75-120 min Larger tanks take longer naturally (not a problem) 1800-209-0909

Brand-Specific Tips:

  • Kent Grand/Supreme: Auto shut-off valve very sensitive to pressure changes. Adjust tank pressure to exactly 7 PSI for best results.
  • Aquaguard RO systems: Pre-sediment filter clogs faster than competitors. Replace every 4-6 months in hard water areas instead of 6-12 months.
  • Livpure models: Tank bladder quality varies. Check air pressure every 3 months and maintain at 6-7 PSI for optimal filling.
  • Pureit by HUL: Many models lack built-in booster pump. If ground floor, add external pump (₹2,500-₹4,000) for reliable tank filling.
  • AO Smith: Larger 10-15L tanks naturally take 90-120 minutes to fill. Don't assume problem unless >150 minutes fill time.
  • Generic/Local brands: Auto shut-off valves often lower quality. Budget ₹500-₹800 for replacement every 2-3 years.

🛡️ Preventive Care & Tank Capacity Management

📅

Every 3 Months

Check storage tank air pressure. Top up to 6-8 PSI if needed. Visually inspect all tube connections for leaks or kinks. Test auto shut-off valve operation.

🔄

Every 6 Months

Replace pre-filters (sediment + carbon) in hard water areas. Every 9-12 months in moderate TDS areas. Monitor tank filling time and document any slowdown.

⚠️

Annual Service

Professional service including TDS check, membrane condition assessment, auto shut-off valve testing, flow restrictor cleaning, complete sanitization. Cost: ₹500-₹1,200.

Tank Capacity Management Tips for Indian Homes:

  • Morning routine: Don't drain entire tank in morning. Leave 2-3 liters so refill is faster.
  • Family size planning: 4-5 member family needs minimum 10L tank, preferably 12L to avoid frequent refills.
  • Peak hour strategy: If on ground floor with low morning pressure, fill tank at night when pressure is better.
  • Backup storage: Keep 2-3 liters in separate clean bottles for emergencies when tank is refilling.
  • Monitor fill cycles: Healthy RO should complete 2-3 fill cycles per day max. More = undersized tank.
  • Monsoon preparation: Replace pre-filters before monsoon season when municipal water sediment increases.
  • Water quality tracking: Monthly TDS check (input vs output). Output should be <50 ppm for drinking.
  • Usage pattern: If tank empties daily, consider upgrading to larger capacity (10L → 15L models available).

Hard Water Area Prevention (Delhi, Chennai, Mumbai, Pune):

  • ✓ Install pre-sediment filter (₹300-₹500) BEFORE RO unit if input TDS >500 ppm - extends main filter life 2x
  • ✓ Consider water softener (₹8,000-₹15,000) for bore water with hardness >300 ppm - reduces membrane fouling
  • ✓ Replace pre-filters every 4-6 months instead of standard 6-12 months in hard water areas
  • ✓ Flush RO system monthly: disconnect reject pipe from drain, let 5-10 liters run to flush membrane scaling
  • ✓ Monitor reject water ratio: Should be 3:1 to 4:1. If >5:1, membrane is fouling and needs replacement soon
  • ✓ Never run RO when municipal supply is visibly muddy/brown (monsoon, pipeline repairs) - damages filters immediately

Frequently Asked Questions

Q: My RO tank fills to only 50-60% and then stops. What's wrong?

Answer: This is almost always an auto shut-off valve malfunction. The pressure-sensing valve is closing prematurely when tank pressure reaches ~4-5 PSI instead of waiting for 6-8 PSI (full tank). Solutions: (1) Try adjusting tank air pressure to exactly 6-7 PSI - sometimes this recalibrates the valve; (2) If that doesn't work, the valve needs professional adjustment or replacement (₹300-₹800). Some valves have a small adjustment screw - turn 1/4 turn counterclockwise to make it close later, but be careful not to over-adjust. If you're not confident, call technician - this is the most common repair they do.

Q: How do I know if the problem is low inlet pressure or something else?

Answer: Simple test: Check tank filling speed at different times of day. If filling time varies significantly: Morning 7-9 AM = 3-4 hours, Night 11 PM-1 AM = 1.5-2 hours → This indicates inlet pressure fluctuation (very common on ground floors). Solution: Install booster pump (₹2,500-₹6,000 total). If filling time is consistently slow (3-4 hours) regardless of time: Problem is internal - clogged filters, fouled membrane, or valve malfunction. Solution: Start with filter replacement DIY, then call technician if no improvement. Additional test: Open inlet tap fully into a bucket - if flow is weak/trickles, pressure is low. If flow is strong, pressure is adequate and problem is internal.

Q: Tank was filling fine, now suddenly takes 6+ hours. What happened?

Answer: Sudden slowdown (vs gradual slowdown) indicates: (1) Municipal water pressure suddenly dropped - Call municipal corporation or check with neighbors if they're experiencing same issue. Temporary solution: Install booster pump. (2) Pre-filter completely clogged - During monsoon or after municipal pipeline repairs, sediment can clog filter in days. Solution: Replace sediment filter immediately (₹200-₹300). (3) Flow restrictor suddenly blocked - Hard water scale can suddenly block the capillary tube. Solution: Professional cleaning (₹150-₹300). (4) Tube got kinked - If RO was moved or cleaned recently, check all tubes for new bends. Gradual slowdown over months indicates normal filter aging and is fixed by regular filter replacement.

Q: Is 2 hours to fill an 8-liter tank normal or too slow?

Answer: 2 hours for 8L tank is at the upper end of normal range but acceptable. Normal range = 60-120 minutes for 8L tank. Calculation: Most RO systems produce 10-15 liters per hour (LPH). At 10 LPH, 8L takes 48 minutes. At 8 LPH (slightly slow), 8L takes 60 minutes. At 4-5 LPH (too slow), 8L takes 90-120 minutes. When to worry: If it previously filled in 60 minutes and now takes 120 minutes = filters aging, need replacement. If it's always been 2 hours since installation = normal for your specific water conditions (high TDS areas take longer). Optimization: Replace pre-filters, check tank air pressure at 6-8 PSI, ensure inlet pressure >40 PSI. You can likely reduce filling time to 60-90 minutes with these steps.

Q: Should I upgrade to a larger storage tank if current one takes too long to refill?

Answer: Not necessarily - larger tank fills even slower! If your 8L tank takes 2 hours, a 12L tank will take 3 hours (same flow rate, more capacity). Better solutions: (1) Fix the root cause: Replace filters, install booster pump, or replace membrane to improve flow rate. A properly functioning RO filling 8L in 60 minutes is better than slow RO filling 12L in 4 hours. (2) Behavior adjustment: Don't drain entire tank in morning. Leave 2-3L so refill is faster. (3) Consider tank upgrade only if: Family size increased (4+ members), you're draining full tank 3+ times daily, and your RO is already functioning optimally (60-90 min fill time). Cost consideration: New larger tank (₹1,500-₹3,000) + possible valve recalibration (₹300-₹500) vs fixing existing system (₹500-₹1,500 for filters/membrane). Usually cheaper to optimize existing system first.

Q: Can I manually fill the tank faster by bypassing the RO membrane temporarily?

Answer: Absolutely not recommended - dangerous to health. Bypassing RO membrane fills tank with untreated water that may contain: bacteria, viruses, heavy metals, pesticides, high TDS, hardness minerals. Why this is tempting but wrong: Yes, tank would fill in 5-10 minutes instead of 1-2 hours, but you defeat the entire purpose of having RO purification. Emergency alternatives if you need water urgently: (1) Boil municipal water in kettle - kills bacteria, ready in 15 minutes (doesn't remove TDS/hardness); (2) Buy packaged drinking water bottles as temporary backup; (3) Keep 5-10L emergency stock in clean bottles, refilled daily; (4) Install larger tank (10-15L) so you rarely run completely dry. Proper solution: Fix the slow filling root cause - filters, pressure, valve - so tank reliably fills in 60-90 minutes naturally.

Q: What's the typical total cost to completely fix a non-filling tank issue?

Answer: Cost varies widely by root cause: Best case (DIY filter replacement): ₹400-₹600 (sediment + carbon filters). Fixes ~60% of slow filling cases. Takes 20 minutes. Valve adjustment/replacement: ₹300-₹800 total (parts + labor). Fixes ~40% of "tank stops at 50%" cases. Takes 30-45 minutes. Tank bladder repressurization: Free if you have bicycle pump, or ₹100-₹200 for pump purchase. Takes 10 minutes. Membrane replacement: ₹1,800-₹4,800 (membrane ₹1,500-₹4,000 + labor ₹300-₹800). Needed if filters are new but filling still slow. Booster pump installation: ₹2,500-₹6,000 total. Permanent fix for low pressure areas. Complete overhaul: ₹3,000-₹6,500 (all filters + membrane + service + minor repairs). Recommended approach: Start with DIY filter replacement (₹500). If no improvement after 24 hours, call technician for professional diagnosis before authorizing expensive repairs.

Q: My tank bladder keeps losing air pressure every 2-3 weeks. Should I keep refilling or replace?

Answer: Replace the tank - bladder has a slow leak and will only get worse. Normal tank bladder should hold 6-8 PSI air pressure for 6-12 months minimum. If pressure drops within 2-3 weeks repeatedly: Bladder rubber is punctured, cracked, or degraded. Temporary refilling is not a solution - you'll be refilling weekly, then daily, then it will fail completely. Cost analysis: Bicycle pump + your time to refill every 2-3 weeks for next 1-2 years = massive hassle. New storage tank = ₹1,200-₹2,500 (one-time cost) and lasts 5-8 years. Warning signs of bladder failure: Pressure drops within 2-3 weeks, water dispensing becomes slower gradually, you hear gurgling sounds from tank, tank feels sloshy when shaken (water on both sides of bladder = bladder ruptured). Replacement options: (1) Genuine brand tank (₹1,800-₹2,500); (2) Compatible generic tank (₹1,200-₹1,800); (3) Upgrade to larger capacity tank if needed (₹2,000-₹3,000 for 12L).

⚠️ Disclaimer: This guide is for informational purposes only. Always follow manufacturer's instructions for your specific RO water purifier model. Use only genuine or certified food-grade replacement parts to ensure water safety. For auto shut-off valve adjustment, membrane replacement, or booster pump installation, consult authorized service technicians. Improper repairs or use of non-food-grade parts can contaminate drinking water and pose health risks. The author and website are not responsible for any damage, water contamination, or health issues arising from DIY repairs. When in doubt, always call a professional technician.

Important Safety Reminder

If you're not comfortable with any step, or if the problem persists after trying these solutions, please contact a qualified technician. Safety should always be your first priority when dealing with electrical appliances.

Discover more helpful guides and reviews to make informed decisions

Need to Buy a New Ro Water-Purifier?

Check out our comprehensive buying guides and reviews

Found this helpful?